Downloads KepserverEX v6.x |
|
OPC Server for Modbus
KepserverEX Modbus Suite
- OPC DA & UA Server
- ThingWorx Connectivity
- Aveva InTouch native driver (SuiteLink)
- GE iFIX Native driver
- OPC Historical DA (HDA) Server (optional)
- OPC A&E Server (optional)
- MQTT Client (optional)
- RESTful Server (optional)
- RESTful Client (optional)
- SNMP Agent (optional)
KepserverEX Modbus SuiteÀº ¾Æ·¡ÀÇ Åë½Å driver¸¦ ¸ðµÎ Æ÷ÇÔÇÏ°í ÀÖ½À´Ï´Ù.
Modbus Master & Slave
- Modbus Master
- Modbus Slave¿¡°Ô data¸¦ ¿äûÇÏ´Â °ÍÀ¸·Î, OPC Server, HMIµîÀÌ Modbus
Master·Î µ¿ÀÛÇÑ´Ù.
- Modbus Slave
- Kepware Modbus OPC Server´Â Modbus TCP/IP Slave, Modbus RTU Slave ·Îµµ
µ¿ÀÛÇÏ¿©, ¾î´À ProtocolÀ̵çÁö Modbus protocol·Î º¯°æÇÒ ¼ö ÀÖ´Ù.
- Protocol convertingÀ» À§Çؼ´Â LinkMaster¸¦ Ãß°¡·Î ÇÊ¿ä·Î ÇÑ´Ù.
Application Support
Supported Devices & Driver Features
Driver
|
Supported
Device
|
Features
|
Modbus Ethernet (Master & Slave)
|
Modbus Ethernet
Applicom: Generic Modbus, TSX Premium, TSX Quantum
Mailbox - Consult your Modicon Documentation on the MSTR instruction for
sending unsolicited requests to the Modbus Ethernet driver
Fluenta FGM
Roxar RFM
Instromet
|
-
Supports Multiple PLCs via IP addressing
Supports Modicon Ethernet to Modbus Plus bridging
Supports Multiple or Single socket usage for better gateway resource
management
Supports Tag import from Concept and ProWORX programming packages
Supports Memory Accesses to 65535
Hex Addressing Support (0-FFFF)
User Definable Read Block Sizes
Adjustable Address Base ( 0 or 1 )
Word Order Swapping for Floating Point and Longs
0xxxx - Output Coils, 1xxxx - Input Coils, 3xxxx - Internal Registers, 4xxxx
- Holding Registers
All data types and arrays are supported
|
Modbus RTU Serial
|
|
-
Supports the TSXCUSBMBP USB adapter for the Modbus Plus Network
Modbus RTU Multi-drop Supported
-
Supports Broadcast Messages using device ID 0
Full Address Range Support ( 0 - 65535 )
Hex Addressing Support (0-FFFF)
User Definable Read Block Sizes
Adjustable Address Base( 0 or 1 )
Word Order Swapping for Floating Point and Longs
Byte Order Swapping on all 16 bit and 32 bit values
Adjustable RTS Flow timing for Radio Modems
Supports all memory types and data types
Support accessing Holding register memory as string data with HiLo/LoHi byte
order
RTU Functions used: 01, 02, 03,04, 05, 06, 16
Supports tag import from Concept and ProWORX programming packages
-
|
Modbus ASCII Serial
|
|
Modbus ASCII Multi-drop Supported
Full Address Range Support ( 0 - 65535 )
User Definable Read Block Sizes
Adjustable Address Base ( 0 or 1 )
Word Order Swapping for Floating Point and Longs
RTU Functions used: 01, 02, 03, 04, 05, 06, 16
Direct Support of Flow Automation flow computers
All memory types and data types supported
|
Modbus Unsolicited Serial (RTU Slave)
|
|
Modbus RTU Multi-drop Supported
Can appear as Multiple Modbus Slave devices
Station numbers selectable from 1-247
Full Address Range Support ( 0 - 65535 )
Hex Addressing Support (0-FFFF)
Adjustable Address Base ( 0 or 1 )
Word Order Swapping on Floating Point and Long
Data Modbus RTU functions accepted by Slave: 01, 02, 03, 04, 05, 06, 16
|
Modbus Plus
|
AT-984 Programmable Controller Board
SA85-PCI
SA85 (-002 and -001) PC Interface Cards
Modbus Plus ISA PC Adapter Card - Schneider part#:
AM-SA85-030
Modbus Plus PCI PC Adapter Card Schneider part#: 416 NHM
300 30
Modbus Plus Type II PCMCIA Card - Schneider part#: 416 NHM
212 30
Modbus Plus Type III PCMCIA Card - Schneider part#: 416 NHM
212 33
Modbus Plus Type III PnP PCMCIA Card - Schneider part#: 416
NHM 212 34
Hilscher CIF Card - For this configuration, the driver
requires Hilscher's SyCon configuration software to be installed on the same
machine as the card. Also, configuration of the card is performed and downloaded
through SyCon
|
-
Supports tag import from Concept and ProWORX programming packages
SA85-PCMCIA (Windows95 only)
Supports up to four SA85 cards in one PC
Supports Multiple Access Paths per card
Modicon X84 w Modbus Plus features
Modicon TIO Remote I/O Modules
Supports Memory Accesses to 65535
0xxxx - Output Coils, 1xxxx - Input Coils, 3xxxx - Internal Registers, 4xxxx
- Holding Registers
Supports accessing Holding Register memory as string data with HiLo/LoHibyte
ordering
All data types and arrays are supported
Order Modicon part # "SW-LNET-INT" or "SW-LNET-I95"
|
|