¼¼»óÀÇ ¸ðµç OPC Server°¡ ´Ù ÀÖ½À´Ï´Ù !!

OPC ±³À° ÇÁ·Î±×·¥ ½Ç½Ã !!  To Download Agenda, click here

OPC by Protocol

Allen-Bradley (Rockwell)

BACnet/IP

DNP3

IEC-60870-5-101 / 104

IEC-61850 (MMS Client)

Fanuc CNC

General Electric (GE)

LS»êÀü XGT / Glofa / Master-K

Manufacturing Suite (100+ Protocols)

Mitsubishi (Melsec)

Modbus (TCP / RTU / ASCII)

ODBC (SQL Server / Oracle / MySQL)

Omron (NJ/CJ/CS)

OPC DA/UA Client

Siemens (S7 200/300/400/1200/1500)

SNMP OPC Server

Downloads

KepserverEX v6.x

  

OPC Server for Fanuc CNC

KepserverEX Fanuc Focas Suite

  • OPC DA & UA Server
  • ThingWorx Connectivity
  • Aveva InTouch native driver (SuiteLink)
  • GE iFIX Native driver
  • OPC Historical DA (HDA) Server (optional)
  • OPC A&E Server (optional)
  • MQTT Client (optional)
  • RESTful Server (optional)
  • RESTful Client (optional)
  • SNMP Agent (optional)

KepserverEX Fanuc Focas SuiteÀº ¾Æ·¡ÀÇ Åë½Å driver¿Í ±â´ÉÀ» Áö¿øÇÕ´Ï´Ù.

  • OPC Server for Fanuc Focas 1 Ethernet
    -
    Focas 1 Ethernet interface library (Fanuc part number A02B-0207-K732) ÇÊ¿ä.
  • OPC Server for Fanuc Focas 2 Ethernet & HSSB (High Speed Serial Bus)
    - Focas 2 Ethernet and HSSB interface library (Fanuc part number A02B-0207-K737) ÇÊ¿ä.
  • i ½Ã¸®Áî CNC controllerÀÇ PMC data ¿µ¿ª Áö¿ø

Application Support

Supported Devices

  • FANUC Series 0i
  • FANUC Series 15
  • FANUC Series 15i
  • FANUC Series 16
  • FANUC Series 16i
  • FANUC Series 18
  • FANUC Series 18i
  • FANUC Series 21
  • FANUC Series 21i
  • FANUC Series 30i
  • FANUC Series 31i
  • FANUC Series 32i
  • FANUC Power Mate i
  • Open Addressing

Supported Address (Memory ¿µ¿ª)

Address Type

Range

A (Message demand)

A00000-A00124
A00000-A00123
A00000-A00121
Axxxxx.0-Axxxxx.7

C (Counter)

C00000-C00199
C00000-C00198
C00000-C00196
Cxxxxx.0-Cxxxxx.7

D (Data table)

D00000-D09999
D00000-D09998
D00000-D09996
Dxxxxx.0-Dxxxxx.7

E (Extended relay)

E00000-E07999
E00000-E07998
E00000-E07996
Exxxxx.0-Exxxxx.7

F (Signal to CNC->PMC)

F00000-F02511
F00000-F02510
F00000-F02508
Fxxxxx.0-Fxxxxx.7

G (Signal to PMC->CNC)

G00000-G02511
G00000-G02510
G00000-G02508
Gxxxxx.0-Gxxxxx.7

K (Keep relay)

K00000-K00909
K00000-K00908
K00000-K00906
Kxxxxx.0-Kxxxxx.7

M (Input signal from other devices)

M00000-M00511
M00000-M00510
M00000-M00508
Mxxxxx.0-Mxxxxx.7

N (Output signal from other devices)

N00000-N00511
N00000-N00510
N00000-N00508
Nxxxxx.0-Nxxxxx.7

R (Internal relay)

R00000-R09119
R00000-R09118
R00000-R09116
Rxxxxx.0-Rxxxxx.7

T (Changeable timer)

T00000-T00299
T00000-T00298
T00000-T00296
Txxxxx.0-Txxxxx.7

X (Signal to machine->PMC)

X00000-X00127
X00000-X00126
X00000-X00124
Xxxxxx.0-Xxxxxx.7

Y (Signal to PMC->machine)

Y00000-Y00127
Y00000-Y00126
Y00000-Y00124
Yxxxxx.0-Yxxxxx.7

Custom Macro Value (common range)

#0100-#0999

Custom Macro Value (local range)

#0001-#0033

Custom Macro Value (system range)

#1000-#9999

 

     

       BridgeWare

°æ±âµµ ¾È¾ç½Ã µ¿¾È±¸ ¹ú¸»·Î 66, A-F1106È£ (ÆòÃÌÇÏÀÌÇʵå)
Phone  031-346-1981(¿µ¾÷) 1982 (Áö¿ø)    Fax  0505-303-1964